Endoscopist deskilling risk after exposure to artificial intelligence in colonoscopy: a multicentre, observational study
Adults / lifelong learning AI and learning
Links to claims
Supports (1)
| Claim | Basis |
|---|---|
| C18 | Polish centres: adenoma detection in non-AI colonoscopy fell from 28.4% to 22.4% after AI polyp detection was introduced. |
Review state: first-pass draft, pending human review.
Source note
Syntes: Endoscopist deskilling risk after exposure to artificial intelligence in colonoscopy: a multicentre, observational study (2025)
Källa: https://doi.org/10.1016/S2468-1253(25)00133-5 (The Lancet Gastroenterology & Hepatology 10(10))
Verified content
- Retrospective observational study at four Polish endoscopy centres in the ACCEPT trial; 1,443 non-AI colonoscopies 3 months before (795) and after (648) AI polyp detection was introduced (abstract).
- Adenoma detection rate in standard, non-AI colonoscopy fell from 28.4% to 22.4% (absolute difference −6.0 percentage points, 95% CI −10.5 to −1.6; p = 0.0089); AI exposure odds ratio 0.69.
Limits
- Observational before/after; short window; cannot separate skill loss from changed behaviour or case mix.
Added 2026-10-16 by the project (broadening, Jonatan approved 2026-10-16); content from the published abstract or well-documented summaries, not a full-text read unless stated.
Metadata as recorded
- ID
- AI-036
- Tier
- observational
- Titel
- Endoscopist deskilling risk after exposure to artificial intelligence in colonoscopy: a multicentre, observational study
- År
- 2025
- Källa/DOI
- https://doi.org/10.1016/S2468-1253(25)00133-5
- Tidskrift
- The Lancet Gastroenterology & Hepatology 10(10)
- Typ
- peer-reviewed article
- Åldersgrupp
- vuxen-livslangt
- Teman
- ai-och-larande
- Hämtad
- 2026-10-16
- Verifierad
- Crossref metadata (title, authors, year, venue) checked 2026-10-16
The original files (PDF or abstract) are kept in the project archive and are not published here.